The Slug Detectors PS-482/484/488 are designed for detecting slugs, double piles driving, and so on, during automatic press working and for outputting stop signal to the press in case of abnormalities.
It reads a signal from Eddy current proximity sensor installed on the mold for the press and calculate the displacement by a microcomputer. If the displacement exceeds the limit, it outputs the stop signal to the press.
Since Ethernet is supported, the PS-482/484/488 can be connected to personal computer (PC) and PLC.
It reads a signal from Eddy current proximity sensor installed on the mold for the press and calculate the displacement by a microcomputer. If the displacement exceeds the limit, it outputs the stop signal to the press.
Since Ethernet is supported, the PS-482/484/488 can be connected to personal computer (PC) and PLC.
✳️ Features
The PS-482/484/488 have the following additional features together with those of our PS-462/464.
Added functions helpful for detection
|
|
Functions helpful for production control
|
|
Ethernet supported
|
✳️ Dimensions
PS-482/484/488
Back view

✳️ Specification
Item | ||
Detect | Channels | 2CH (PS-482) / 4CH (PS-484) / 8CH (PS-488) |
Resolution | 1μm or 0.1μm | |
Max. limit value | 200μm or 20.0μm | |
Detect mode | Internal timing, External timing | |
Max. SPM | 4000SPM | |
Sensor | Sensor Installation distance (at B.D.C.) |
0.7 to 1.5 mm |
Length of sensor cable | 1 to 10m (Standard 3m) | |
Temperature | 0 to 55°C | |
Input/Output | Power source voltage | 100 to 240 VAC ±10%,50/60Hz (Max. 40VA) |
Relay output | EMG Stop, TDC Stop, READY,ALARM (Max. 250VAC / 30VDC 3.0A) |
|
External input | ON/OFF, RESET, LOCK, TIMING (T1, T2, T3) | |
Open collector output |
AUX (5 to 24 VDC 100mA) | |
Ethernet | Physical layer | 10BASE-T/100BASE-TX |
Protocol | IPv4 UDP、DHCP、HTTP、Telnet、FTP |
|
Others | Dimensions of the body | 200(W)× 98.5(H)×190(D) excluding projections |
Weight | 3.0 kgW (inc. mounting bracket) | |
Temperature | 0 to 55°C (must not be sudden change while using it) | |
Humidity | 35 to 85%RH (no dew condensation allowed) |
✳️ Sensor heads
Only the mechanical dimentions are different,the electric characteristic are all the same.
Click on image for more infomation. | ||||||
PS-4013 | PS-4014 | PS-4018 | PS-4020 | PS-4024 | PS-4025 | PS-4026 |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
PS-4027 | PS-4028 | PS-4029 | PS-4031 | PS-4032 | PS-4033 | PS-4034 |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
✳️ Sensor Cable Series of 243297
The colors of the sensor cable are blue, red, yellow, and white.
blue red white yellow Sensor Cable Series of 243297 Order codes ✳️Contact us immediately for advice and best quotes!